Ignition transformers, four voltage classes
Every burner platform we are asked to supply falls into one of four bands. They share the same EI core, Class H winding, vacuum impregnation and epoxy potting — what changes between them is the stack, the turns ratio and the thermal mass.
Compact & commercial
The highest-volume band. Gas burners, wall-hung boilers, packaged rooftop units and small industrial burners where the electrode gap is short and the burner cycles often.
| Parameter | Typical value |
|---|---|
| Output, peak | 2 × 4 kV / 6 kV |
| Secondary current | 20 – 25 mA |
| Input | 120 V / 230 V, 50–60 Hz |
| Duty cycle | 100 % continuous |
| Termination | Porcelain post, end or centre-tap grounded |
| Models | KTX-406 · KTX-423 · KTX-606 · KTX-620 |
Where it goes
- Atmospheric and forced-draft gas burners
- Wall-hung and floor-standing domestic boilers
- Rooftop and packaged HVAC units
- Small process heaters with a 2–3 mm gap
This band is where private-label volume lives. A distributor can take a KTX-606 with its own nameplate, carton and insert and hold it against a 1092-class part.
Industrial gas & light oil
Industrial gas trains, dual-electrode burners and packaged boilers. Usually cabinet-mounted, usually intermittent, and usually where a customer first asks about duty cycle rather than price.
| Parameter | Typical value |
|---|---|
| Output, peak | 5 / 7 / 8 kV |
| Secondary current | 15 – 40 mA |
| Input | 100 – 230 V, 50–60 Hz |
| Duty cycle | 20 % (3 min / 12 min) or 50 % |
| Termination | Dual post, flying leads, or push-on |
| Models | KTX-715 · KTX-820 · KTX-721 · KTX-750 |
Where it goes
- Industrial gas burners with ionisation flame detection
- Dual-electrode and single-electrode burner fronts
- Light-oil burners and packaged boiler trains
- Cabinet-mounted burner controls, IP20
KTX-721 is the dual-voltage variant for 100/200 V supplies — the specification Japanese and some Southeast Asian burner platforms use.
Heavy oil & large furnace
Heavy-oil burners, large industrial furnaces and utility boiler fronts, where the electrode gap is wide, the fuel is cold and the ignition has to happen on the first try.
| Parameter | Typical value |
|---|---|
| Output, peak | 10 / 15 / 17.5 kV |
| Secondary current | 22 – 45 mA |
| Input | 120 V / 230 V / 240 V |
| Duty cycle | 20 % intermittent / 100 % on the large stack |
| Termination | Porcelain post, mid-point grounded option |
| Models | KTX-1022 · KTX-1525 · KTX-1754 |
Where it goes
- Heavy-oil and waste-oil burners
- Large industrial furnaces and kilns
- Utility and process boiler fronts
- Cold-start duty where the first spark has to land
The 250 VA class (KTX-1022) is the part most often asked to match a North American 10 kV housing inch for inch.
High-energy ignition
The upper end: large heavy-oil burners, cold and humid conditions, oversized electrode gaps. Fewer units, but this is where an unreliable transformer becomes a plant shutdown.
| Parameter | Typical value |
|---|---|
| Output, peak | 20 / 26 kV |
| Secondary current | 40 – 48 mA |
| Input | 230 V, 50–60 Hz |
| Duty cycle | 20 % / 50 % |
| Termination | Dual porcelain post, wide spacing, creepage per drawing |
| Models | KTX-2040 · KTX-2648 |
Where it goes
- Large heavy-oil burner fronts
- High-power industrial furnaces
- Cold-climate and high-humidity installations
- Burners with a long, exposed electrode path
At this level potting quality decides life. A void in the cast shows up as corona erosion months later, not on the test bench.
The other architecture:
electronic.
Same job, different physics. A ferrite step-up driven by a switching module instead of a 50/60 Hz EI stack — smaller, lighter, constant spark rate, and the part most new burner platforms are designed around. We take OEM and ODM programs on this side too, on the same terms as the inductive range.
| Parameter | Typical value |
|---|---|
| Output, peak | 4 – 20 kV |
| Input | 12 / 24 V DC · 120 / 230 V AC |
| Spark rate | 20 – 100 Hz, set at build |
| Spark energy | 20 – 120 mJ |
| Duty cycle | 100 % continuous |
| Encapsulation | Epoxy potted module or open-frame board in your housing |
| Termination | Flying leads · screw terminals · plug-in connector |
| Models | KTX-E4 · KTX-E8 · KTX-E12 · KTX-E20 |
Series names and figures describe our platform envelope, not a released catalogue. Final numbers are fixed on the approved drawing.
Where it goes
- Modern gas and oil burners with a packaged control board
- Pellet, biomass and condensing appliances where space is tight
- Rooftop and packaged units that see vibration and moisture
- Retrofit kits replacing an oversized inductive can
Electronic and inductive are not drop-in interchangeable. The burner's ignition sequence, electrode lead length and supply have to be checked before a swap — we ask for that before quoting, not after.
OEM to your board
You keep the control board and the ignition sequence. We build the high-voltage module to your schematic, housing and connector, and test it against your acceptance limits.
ODM platform
Start from our potted module: fix the input, output and spark rate, then change the lead length, connector and label. Your brand goes on the part and the packaging.
Build & test in Wujiang
Potting, termination, burn-in and 100% spark test stay in the same plant that runs the inductive line. Driver boards come from a controlled local PCB partner under our incoming inspection.
Certification route is agreed per program — component-level UL/CSA recognition or CE on the assembly, whichever your end product needs.
Three things that
decide the part.
Two quotations that look identical on the output voltage can differ by half the copper. These three parameters are settled before price, not after.
Duty cycle
20% ED means 3 minutes on, 12 off. 100% continuous needs a larger stack and more copper — typically 40–60% more material. A continuous-duty part is never the same hardware with a different label.
Grounding arrangement
End-grounded, mid-point grounded and centre-tap grounded are different secondaries, not different labels. It changes the terminal block, the creepage and the insulation test profile.
Housing & terminals
Footprint, mounting centres, terminal spacing and lead length are what a burner OEM actually rejects a sample for. We compare them dimension by dimension before tooling.
Match a rating to a platform model in the cross-reference table →