Home / Cross-reference

Start from a part you already run

Give us the housing you have and the rating you need. This table maps the ratings that dominate the burner market to our platform models, so the first conversation starts from dimensions and figures instead of a blank page.

Kmwell model Band Input Output (peak) Current Duty Typical reference rating
KTX-4064–6230 V2 × 4 kV20 mA100%Compact 8/20 class · Riello-type housings
KTX-4234–6230 V2 × 4 kV23 mA19% / 3 minTRE820 class · centre-tap grounded
KTX-6064–6120 V6 kV25 mA100%1092 / A06-SA6 class · end-grounded
KTX-6204–6240 V6 kV20 mA100%1196 / 1112 class · continuous ferromagnetic
KTX-7157–8230 V5 kV15 mA20%TZI 5-15 class · cabinet mount, IP20
KTX-8207–8230 V8 kV20 mA20%TZI 7.5-20 class · 20 kHz output stage
KTX-7217–8100/200 V7 kV21 / 16 mAIntermittentG10M23 class · dual-voltage, 2 mm gap
KTX-7507–8230 V2 × 7.5 kV40 mA50%EBI 4 M class · dual output
KTX-102210–15120 V10 kV22 mA100%A10-LA2 class · 250 VA, mid-point grounded
KTX-152510–15230 V15 kV25 mA20%TC1 class · single pole
KTX-175410–15240 V17.5 kV45 mA100%2280 class · mid-point grounded kit
KTX-204020–26230 V20 kV40 mA20%TSC class · high-power industrial furnace
KTX-264820–26230 V26 kV48 mA50%26/48 class · heavy-oil burner dual pole

13 of 13 models

Reference ratings describe the market segment and typical figures, not electrical identity with any specific product. Brand and model names cited belong to their respective owners and imply no affiliation or approval. Final dimensions, terminals and nameplate data are fixed on the approved drawing.

How to use it

Three steps from
a rating to a sample.

The table narrows the electrical case. The housing still has to be confirmed, and that takes a drawing or a physical sample — either is enough to start.

Step 01

Pick the band

Output peak, current and duty cycle first. If the duty cycle is unknown, send the burner's ignition sequence — 3 minutes on is a different part from continuous duty.

Step 02

Confirm the housing

Footprint, mounting centres, terminal spacing, lead length. Send a drawing or the part itself; we return a dimensional comparison listing every difference before tooling.

Step 03

Take free samples

Two to five units with a test report, in 10 days. Your lab breaks them, tells us what failed, and we either fix the design or confirm the drawing.

If your part is not listed

Most enquiries are not on any table.

Send the nameplate photo and the burner model. If the housing is custom, that is the normal case — roughly half of our programs start from a part that exists only in the customer's drawing archive.

What to send
Required
Nameplate photo or drawing · input voltage · duty cycle
Helpful
Burner make and model · annual volume · certification route
Optional
Target price · current supplier · packaging constraints

Not sure which model fits? Send the nameplate.

Send the detail