Start from a part you already run
Give us the housing you have and the rating you need. This table maps the ratings that dominate the burner market to our platform models, so the first conversation starts from dimensions and figures instead of a blank page.
| Kmwell model | Band | Input | Output (peak) | Current | Duty | Typical reference rating |
|---|---|---|---|---|---|---|
| KTX-406 | 4–6 | 230 V | 2 × 4 kV | 20 mA | 100% | Compact 8/20 class · Riello-type housings |
| KTX-423 | 4–6 | 230 V | 2 × 4 kV | 23 mA | 19% / 3 min | TRE820 class · centre-tap grounded |
| KTX-606 | 4–6 | 120 V | 6 kV | 25 mA | 100% | 1092 / A06-SA6 class · end-grounded |
| KTX-620 | 4–6 | 240 V | 6 kV | 20 mA | 100% | 1196 / 1112 class · continuous ferromagnetic |
| KTX-715 | 7–8 | 230 V | 5 kV | 15 mA | 20% | TZI 5-15 class · cabinet mount, IP20 |
| KTX-820 | 7–8 | 230 V | 8 kV | 20 mA | 20% | TZI 7.5-20 class · 20 kHz output stage |
| KTX-721 | 7–8 | 100/200 V | 7 kV | 21 / 16 mA | Intermittent | G10M23 class · dual-voltage, 2 mm gap |
| KTX-750 | 7–8 | 230 V | 2 × 7.5 kV | 40 mA | 50% | EBI 4 M class · dual output |
| KTX-1022 | 10–15 | 120 V | 10 kV | 22 mA | 100% | A10-LA2 class · 250 VA, mid-point grounded |
| KTX-1525 | 10–15 | 230 V | 15 kV | 25 mA | 20% | TC1 class · single pole |
| KTX-1754 | 10–15 | 240 V | 17.5 kV | 45 mA | 100% | 2280 class · mid-point grounded kit |
| KTX-2040 | 20–26 | 230 V | 20 kV | 40 mA | 20% | TSC class · high-power industrial furnace |
| KTX-2648 | 20–26 | 230 V | 26 kV | 48 mA | 50% | 26/48 class · heavy-oil burner dual pole |
13 of 13 models
Reference ratings describe the market segment and typical figures, not electrical identity with any specific product. Brand and model names cited belong to their respective owners and imply no affiliation or approval. Final dimensions, terminals and nameplate data are fixed on the approved drawing.
Three steps from
a rating to a sample.
The table narrows the electrical case. The housing still has to be confirmed, and that takes a drawing or a physical sample — either is enough to start.
Pick the band
Output peak, current and duty cycle first. If the duty cycle is unknown, send the burner's ignition sequence — 3 minutes on is a different part from continuous duty.
Confirm the housing
Footprint, mounting centres, terminal spacing, lead length. Send a drawing or the part itself; we return a dimensional comparison listing every difference before tooling.
Take free samples
Two to five units with a test report, in 10 days. Your lab breaks them, tells us what failed, and we either fix the design or confirm the drawing.
Most enquiries are not on any table.
Send the nameplate photo and the burner model. If the housing is custom, that is the normal case — roughly half of our programs start from a part that exists only in the customer's drawing archive.
- Required
- Nameplate photo or drawing · input voltage · duty cycle
- Helpful
- Burner make and model · annual volume · certification route
- Optional
- Target price · current supplier · packaging constraints